  Products :
 
 

 

 
 
Castle series UPS C1K/C1KS, C2K/C2KS, C3K/C3KS

                          

The Castle series On-line UPS is an advanced true double conversion On-line Topology, the Castle Isolated gate Bipolar Transistors (IGBT) for true isolation from AC input.  Ideal for Data Centers in network and Industrial applications. Features scalable battery packs for those critical business systems that require long run times.  With the Castle wide in-put voltage range and near zero tolerance on frequency and voltage variance on the put-put the Castle series is perfect for the most demanding and delicate of applications.

Sine-wave output:
True sine-wave output with less than 3% THD.

Double Conversion Design:
Zero transfer/ complete isolation of input AC.

UPS Monitoring Software:
Powerful true RS232 communication via the enclosed software
to manage and safely shutdown operating systems.

Network RJ45/11 protection:
Complete powerful network and phone line surge protection.

AC Surge Suppressor:
Powerful multi-stage surge components that exceed IEEE requirements.

SNMP Slot Option:
Allows for remote monitoring and control via www.

Sleep Mode:
Worry free battery management. The unit turns itself off after ten seconds to conserve battery
power when no power needs are detected.

Battery level indicators:
LED''s indicate battery levels.

Load Sensing:
The incorporated LED load indicators allow IT professionals to manage backup time and balance
power loads.

Low Battery indicators:
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts
down.

Replace Battery indicators:
A preventative measure that indicates when batteries must be replaced to prevent
server crashes.


TECHNICAL SPECIFICATIONS:

Product Series

CASTLE

Model

C1K

C2K

C3K

Rated Power

VA/W

1kVA / 0.7kW

2kVA / 1.4kW

3kVA / 2.1kW

Input

Nominal Voltage

220VAC

Voltage Range

115 ~ 300VAC

Frequency Range

46~54Hz(default), user adjustable within 40~60Hz

Power Factor

0.97

Connection

IEC320-10A inlet

IEC320-16A inlet

Output

Voltage

220VAC ¡À 2%

Frequency

46~54Hz or 50Hz ¡À 0.2Hz (Line mode)
50Hz ¡À 0.2Hz ( Battery mode)

Waveform

Sine Wave

Distortion

3%

4%

Overload Capability

108%~150% for 30 sec., ³150% for 300 ms

Current Crest Ratio

3:1

Connections

IEC320 * 4

IEC320 * 6

IEC320 * 3 and
Terminal Block

Battery

Type

Sealed, Maintenance free, Lead-Acid

Quantity

3 pieces

8 pieces

Back-up Time (Full load)

5 min

9 min

5 min

Recharge Time

5 hrs to 90% of capacity after full load discharge

Bypass 

 

Automatic Transfer

on overload and UPS failure

Before UPS Power-on

Default ¡°NO¡±, user adjustable to ¡°YES¡±

Voltage Range

80~264VAC (Default), user adjustable within 80~286VAC

Transfer Time

0 ms; less than 4 ms from inverter to bypass and vice versa

LED Indicators

Status

Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault

Audible Alarm

Bypass, On battery mode, Battery low, Overload, Fault

Acoustic Noise

At 1 meter distance

45 dBA

50 dBA

Communications

DB-9 Port

RS-232 Serial Interface

Intelligent Slot

Options: WebPower, AS400 Card or WinPower CMC

Network Surge Protection

RJ45 I/O port available for network or Fax/Modem

Environmental

Operating Temperature

0 ~ 40¡ãC

Operating Humidity

20 ~ 90% non-condensing

Weight

Net (Kg)

13

31.5

32

Dimensions

W x D x H (mm)

145 x 400 x 220

192 x 460 x 348

 

Model

C1KS

C2KS

C3KS

Rated Power

VA/W

1kVA / 0.7kW

2kVA / 1.4kW

3kVA / 2.1kW

Input

Nominal Voltage

220VAC

Voltage Range

115 ~ 300VAC

Frequency Range

46 ~ 54Hz(default), user adjustable within 40~60Hz

Power Factor

0.97

Connection

IEC320-10A inlet

IEC320-16A inlet

Output

Voltage

220VAC ¡À 2%

Frequency

46~54Hz or 50Hz ¡À 0.2Hz (Line mode)
50Hz ¡À 0.2Hz ( Battery mode)

Waveform

Sine Wave

Distortion

3%

4%

Overload Capability

108% ~ 150% for 30 sec., ³150% for 300 ms

Current Crest Ratio

3:1

Connections

IEC320-10A *4

IEC320-10A *6

IEC320-10A *3 and
Terminal Block

Battery

 

Type

Sealed, Maintenance free, Lead-Acid

Nominal DC Voltage

36VDC

96VDC

Back-up Time

Depends on the capacity of the external battery bank

Connection

External Battery Socket

Bypass

 

Automatic Transfer

On overload and UPS failure

Before UPS Power-on

Default ¡°NO¡±, user adjustable to ¡°YES¡±

Voltage Range

80 ~ 264VAC (Default), user adjustable within 80 ~ 286VAC

Transfer Time

0 ms; less than 4 ms from inverter to bypass and vice versa

LED Indicators

Status

Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault

Audible Alarm

Bypass, On battery mode, Battery low, Overload, Fault

Acoustic Noise

At 1 meter distance

45 dBA

50 dBA

Communications

DB-9 Port

RS-232 Serial Interface

Intelligent Slot

Options: WebPower, AS400 Card or WinPower CMC

Network Surge Protection

RJ45 I/O port available for 10 base-T network or Fax/Modem

Environmental

Operating Temperature

0 ~ 40¡ãC

Operating Humidity

20 ~ 90% non-condensing

Weight

Net (Kg)

7

13.5

14

Dimensions

W x D x H (mm)

145 x 400 x 220

192 x 460 x 348

 

 
 
 