Chinese   |    Battery   |    Site Map   |    Friendly Links
Homepage About Us Products OEM Download Support Message Contact Online
 
 
  Products Search :
 
  Products Classification :
 
  Off-Line UPS
 
  Line Interactive UPS
 
  Online UPS
 
  Inverter
 
  Battery charger
 
  Voltage Regulators (AVR)
 
  Power distribution Units (PDU)
 
  Solar Power Inverter
 
  Battery
 
  Reference Links :
 
  The modernist Online & Line Interactive UPS...
 
  These kinds of UPS, which are used in data...
 
 
  Contact Online
 
  Msn Online
 
Merrily
Katherine
 
Cleo
Candy
 
 
  Products :
 
 

 

 
 
Castle LCD Series UPS 1K-20KVA

 

KEY FEATURES

• Microprocessor Control Guarantees High Reliability
• Comprehensive Self-Protection Design
• Audible Alarm Mute
• Cold Start Function
• Auto Self-Testing System while Turning On UPS
• Wide Input Voltage Range
• Maintenance Bypass Switch for 6K/ 10K
• N+X Parallel Redundancy and Capacity Expansion for 6K/ 10K

TECHNICAL SPECIFICATIONS :

 

Product Series

CASTLE

Model

B1K

B2K

  B3K 

Rated Power

VA/W

1kVA / 0.7kW

2kVA / 1.4kW

3kVA / 2.1kW

Input

Nominal Voltage

220VAC

Voltage Range

115 ~ 300VAC

Frequency Range

46~54Hz(default), user adjustable within 40~60Hz

Power Factor

0.97

Connection

IEC320-10A inlet

IEC320-16A inlet

Output

Voltage

220VAC ¡À 2%

Frequency

46~54Hz or 50Hz ¡À 0.2Hz (Line mode)
50Hz ¡À 0.2Hz ( Battery mode)

Waveform

Sine Wave

Distortion

3%

4%

Overload Capability

108%~150% for 30 sec., ³150% for 300 ms

Current Crest Ratio

3:1

Connections

IEC320 * 4

IEC320 * 6

IEC320 * 3 and
Terminal Block

Battery

Type

Sealed, Maintenance free, Lead-Acid (Panasonic)

Quantity

3 pieces

8 pieces

Back-up Time (Full load)

5 min

9 min

5 min

Recharge Time

5 hrs to 90% of capacity after full load discharge

Bypass 

 

Automatic Transfer

on overload and UPS failure

Before UPS Power-on

Default ¡°NO¡±, user adjustable to ¡°YES¡±

Voltage Range

80~264VAC (Default), user adjustable within 80~286VAC

Transfer Time

0 ms; less than 4 ms from inverter to bypass and vice versa

LCD Indicators

Status

Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault

Audible Alarm

Bypass, On battery mode, Battery low, Overload, Fault

Acoustic Noise

At 1 meter distance

45 dBA

50 dBA

Communications

DB-9 Port

RS-232 Serial Interface

Intelligent Slot

Options: WebPower, AS400 Card or WinPower CMC

Network Surge Protection

RJ45 I/O port available for network or Fax/Modem

Environmental

Operating Temperature

0 ~ 40¡ãC

Operating Humidity

20 ~ 90% non-condensing

Weight

Net (Kg)

13

31.5

32

Dimensions

W x D x H (mm)

145 x 400 x 220

192 x 460 x 348

 

Model

B1KS

B2KS

B3KS

Rated Power

VA/W

1kVA / 0.7kW

2kVA / 1.4kW

3kVA / 2.1kW

Input

Nominal Voltage

220VAC

Voltage Range

115 ~ 300VAC

Frequency Range

46 ~ 54Hz(default), user adjustable within 40~60Hz

Power Factor

0.97

Connection

IEC320-10A inlet

IEC320-16A inlet

Output

Voltage

220VAC ¡À 2%

Frequency

46~54Hz or 50Hz ¡À 0.2Hz (Line mode)
50Hz ¡À 0.2Hz ( Battery mode)

Waveform

Sine Wave

Distortion

3%

4%

Overload Capability

108% ~ 150% for 30 sec., ³150% for 300 ms

Current Crest Ratio

3:1

Connections

IEC320-10A *4

IEC320-10A *6

IEC320-10A *3 and
Terminal Block

Battery

 

Type

Sealed, Maintenance free, Lead-Acid

Nominal DC Voltage

36VDC

96VDC

Back-up Time

Depends on the capacity of the external battery bank

Connection

External Battery Socket

Bypass

 

Automatic Transfer

On overload and UPS failure

Before UPS Power-on

Default ¡°NO¡±, user adjustable to ¡°YES¡±

Voltage Range

80 ~ 264VAC (Default), user adjustable within 80 ~ 286VAC

Transfer Time

0 ms; less than 4 ms from inverter to bypass and vice versa

LCD Indicators

Status

Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault

Audible Alarm

Bypass, On battery mode, Battery low, Overload, Fault

Acoustic Noise

At 1 meter distance

45 dBA

50 dBA

Communications

DB-9 Port

RS-232 Serial Interface

Intelligent Slot

Options: WebPower, AS400 Card or WinPower CMC

Network Surge Protection

RJ45 I/O port available for 10 base-T network or Fax/Modem

Environmental

Operating Temperature

0 ~ 40¡ãC

Operating Humidity

20 ~ 90% non-condensing

Weight

Net (Kg)

7

13.5

14

Dimensions

W x D x H (mm)

145 x 400 x 220

192 x 460 x 348

  

 

 
 
 
Copyright © 2004-2006 Santakups Company Limited, All Rights Reserved.