Castle LCD Series UPS 1K-20KVA
KEY FEATURES
• Microprocessor Control Guarantees High Reliability • Comprehensive Self-Protection Design • Audible Alarm Mute • Cold Start Function • Auto Self-Testing System while Turning On UPS • Wide Input Voltage Range • Maintenance Bypass Switch for 6K/ 10K • N+X Parallel Redundancy and Capacity Expansion for 6K/ 10K
TECHNICAL SPECIFICATIONS :
Product Series
CASTLE
Model
B1K
B2K
B3K
Rated Power
VA/W
1kVA / 0.7kW
2kVA / 1.4kW
3kVA / 2.1kW
Input
Nominal Voltage
220VAC
Voltage Range
115 ~ 300VAC
Frequency Range
46~54Hz(default), user adjustable within 40~60Hz
Power Factor
0.97
Connection
IEC320-10A inlet
IEC320-16A inlet
Output
Voltage
220VAC ¡À 2%
Frequency
46~54Hz or 50Hz ¡À 0.2Hz (Line mode) 50Hz ¡À 0.2Hz ( Battery mode)
Waveform
Sine Wave
Distortion
3%
4%
Overload Capability
108%~150% for 30 sec., ³150% for 300 ms
Current Crest Ratio
3:1
Connections
IEC320 * 4
IEC320 * 6
IEC320 * 3 and Terminal Block
Battery
Type
Sealed, Maintenance free, Lead-Acid (Panasonic)
Quantity
3 pieces
8 pieces
Back-up Time (Full load)
5 min
9 min
5 min
Recharge Time
5 hrs to 90% of capacity after full load discharge
Bypass
Automatic Transfer
on overload and UPS failure
Before UPS Power-on
Default ¡°NO¡±, user adjustable to ¡°YES¡±
Voltage Range
80~264VAC (Default), user adjustable within 80~286VAC
Transfer Time
0 ms; less than 4 ms from inverter to bypass and vice versa
LCD Indicators
Status
Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault
Audible Alarm
Bypass, On battery mode, Battery low, Overload, Fault
Acoustic Noise
At 1 meter distance
45 dBA
50 dBA
Communications
DB-9 Port
RS-232 Serial Interface
Intelligent Slot
Options: WebPower, AS400 Card or WinPower CMC
Network Surge Protection
RJ45 I/O port available for network or Fax/Modem
Environmental
Operating Temperature
0 ~ 40¡ãC
Operating Humidity
20 ~ 90% non-condensing
Weight
Net (Kg)
13
31.5
32
Dimensions
W x D x H (mm)
145 x 400 x 220
192 x 460 x 348
Model
B1KS
B2KS
B3KS
Rated Power
VA/W
1kVA / 0.7kW
2kVA / 1.4kW
3kVA / 2.1kW
Input
Nominal Voltage
220VAC
Voltage Range
115 ~ 300VAC
Frequency Range
46 ~ 54Hz(default), user adjustable within 40~60Hz
Power Factor
0.97
Connection
IEC320-10A inlet
IEC320-16A inlet
Output
Voltage
220VAC ¡À 2%
Frequency
46~54Hz or 50Hz ¡À 0.2Hz (Line mode) 50Hz ¡À 0.2Hz ( Battery mode)
Waveform
Sine Wave
Distortion
3%
4%
Overload Capability
108% ~ 150% for 30 sec., ³150% for 300 ms
Current Crest Ratio
3:1
Connections
IEC320-10A *4
IEC320-10A *6
IEC320-10A *3 and Terminal Block
Battery
Type
Sealed, Maintenance free, Lead-Acid
Nominal DC Voltage
36VDC
96VDC
Back-up Time
Depends on the capacity of the external battery bank
Connection
External Battery Socket
Bypass
Automatic Transfer
On overload and UPS failure
Before UPS Power-on
Default ¡°NO¡±, user adjustable to ¡°YES¡±
Voltage Range
80 ~ 264VAC (Default), user adjustable within 80 ~ 286VAC
Transfer Time
0 ms; less than 4 ms from inverter to bypass and vice versa
LCD Indicators
Status
Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault
Audible Alarm
Bypass, On battery mode, Battery low, Overload, Fault
Acoustic Noise
At 1 meter distance
45 dBA
50 dBA
Communications
DB-9 Port
RS-232 Serial Interface
Intelligent Slot
Options: WebPower, AS400 Card or WinPower CMC
Network Surge Protection
RJ45 I/O port available for 10 base-T network or Fax/Modem
Environmental
Operating Temperature
0 ~ 40¡ãC
Operating Humidity
20 ~ 90% non-condensing
Weight
Net (Kg)
7
13.5
14
Dimensions
W x D x H (mm)
145 x 400 x 220
192 x 460 x 348