Castle Series LCD 3C10KS-3C20KS

Power Range:3C10KS-3C20KS

Type:Online

Description:The Castle series On-line UPS is an advanced true double conversion On-line Topology, the Castle Isolated gate Bipolar Transistors (IGBT) for true isolation from AC input.Ideal for Data Centers in network and Industrial applications.Features scalable battery packs for those critical business systems that require long run times.

contact now





    • Features
    • Specifications
    Servers, Data centers, Critical network devices, Sensitive electronic equipment, Telecom.
    • Online-Double conversion
    • Non Transfer Time of output
    • PFC technology
    • Full digital control (DSP)
    • Output power factor: 0.8
    • Input current harmonic: 5%
    • ECO function
    • Charging/Rectifier/Inverter fully digital control technology
    • Optimization battery group, the quantity of battery: 16/18/20 pieces (optional)
    • Wide input voltage range: 304~478VAC
    • Wide input frequency range: 40~70Hz±0.5Hz
    • Self-testing when UPS startup
    • Input over/under-voltage protection
    • Automatic bypass
    • DC start
    • Fault isolation
    • Comunication port: RS232 , dry contact,RS485*2
    • Options: SNMP card/Centralized monitoring card/ Parallel port module
    High Frequency Online UPS Castle Series UPS  
    3C10KS  3C15KS  3C20KS 10KVA  15KVA  20KVA Specifications

    Output
    Capacity 3C10KS 3C15KS 3C20KS
    Rated Power 10000VA/8000W  15KVA/12KW 20KVA/16KW
    Output Voltage 208VAC/220VAC/230VAC/240VAC
    Voltage Waveform Pure Sine Wave
    Crest Factor 3:01
    Output Frequency
    (Synchronized- Mains)
    46~54Hz Or 56Hz - 64Hz (Line Mode)50/60HZ/ ±0.05Hz( Battery Mode) 
    Regulation(Nominal) ±1%
    Regulation
    (Battery Mode)
    ±1%
    Transfer Time Zero
    Over Current Protection Line Mode:10min@100%~130%;Battery Mode:30s@100%~130%
    Outlet Hard Wiring With Terminal Block 
    Harmonic Distortion ≤2%THD(Linear Load);≤5%THD(Non-Linear Load)
    Input
    Capacity 3C10KS  3C15KS 3C20KS
    Nominal Voltage 277-520VAC@Full Load
    Input Frequency 46~54Hz / 56~60Hz
    Efficiency 90% (AC Mode)   90%(Battery Type)
    Noise Filtering Full Time EMI/RFI Filtering
    Over Current Protection By AC Fuse Or By Re-Settable Over Current   Protector 
    AVR Range
    (2 Bucks,2 Boosts)
    Enhanced Buck: +15% Of Selected Nominal Voltage
    Buck Mode: +5% Of Selected Nominal Voltage
    Boost Mode: -5% Of Selected Nominal Voltage
    Enhanced Boost: -12.5% Of Selected Nominal Voltage
    Phase Three Phase Input and Single Phase Output
    Battery
    Battery Type Sealed Lead Acid Battery.
    Rated Charging Voltage Depending On The Capacity Of External Batteries
    Typical Backup Time Depending On The Capacity Of External Batteries
    Charging Method Smart Pulse Charging With Two Charging Modes.
    Quick Charging When Battery Is Not Fully Charged,
    Trickle Charging When Battery Is 90% Fully Charged.
    Charging Current(MAX) 4.0/8.0A  
    Protection Over Current Protection & OverCharging Voltage
    Protection (SCRControl) Thermal Protection (CPU Control)
    When Temperature Inside UPS Is Over 45℃, Charger Will Stop
    Charging For 2.5 Minutes Followed By An 1.5 Minutes Charging.   
    The Cycle Will BeRepeated Until The Temperature is Lower Than 44℃.
    Temperature Compension Yes
    Numbers Of Battery DC192V, Depending On The Capacity Of External Batteries
    Optional Features
    ECO Mode Support
    CVCF Support
    PDU Support
    Remote Panel Wired Type, Up To 100M Length
    Parallel Redundancy Up To 4 Units Max (Option)
    Environmental And Safety
    Operating Temperature 0℃ To 40℃ (32℉ To 104℉)
    Transit/Storage
    Temperature
    -15℃ To 55℃ (5℉ To 131℉)
    Relative Humidity 20-90%(NON-CONDENSING)
    Operating Altitude 0 ~ 3000 Meters
    Audible Noise ≦50 Dba
    Safety Markings BSMI CE
    EMC Class B, EN50091-2, FCC Part15, IEC1000-2-2
    Quality Control System ISO 9001:2000
    Noise Level <60db@1 Meter
    Indicator
    LED Version Load Level/Battery Level/Battery Mode; AC Mode/Bypass Mode/Fault
    Battery Mode Sounding Every 4 Seconds
    Low Battery Sounding Every Second
    Overload  Sounding Twice Every  Second
    Fault Continously Sounding 
    LCD Version Load/Battery/Input/Output/Operating;Mode Information
    Interface
    Smart RS-232 Software Supports Windows Family. Sun Solaris,
    IBM Aix, Compaq True64,SGIIRIX ,Freebsd.HP-UX, And MAC
    USB (Option) Windows Family& MAC
    Internal Slot(Option) SNMP/AS400 Relay Card/Rs485 (Option)
    EPO(Option) Support Emergency Shutdown
    Physical
    Dimensions:
    (D×H×W)mm
    595*390*578mm
    N.W/G.W (Kg) 595*390*578mm
    N.W/G.W (Kg) 3C10KS:27 3C15KS:35 3C20KS:35
    Packing Standard Packing, Export Carton For Each Unit