Castle 3C3 EX UPS

Power Range:

Type:Online

Description:The series product is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. Castle EX series UPS provide customers safe and sound power supply.

contact now





    • Features
    • Specifications
    CASTLE EX series UPS is converted to DC through an individual PFC circuit and then transferred to AC through Inverter for output. At the same time, a separate controller is provided for the real time control and data collection of PFC circuit so that the whole system can operate more harmonious or feedback the system state to the customer more promptly. In addition, the controlling of battery charging can extend the battery's serve lifetime effectively and the twin-channel line input improves the system's reliability. Furthermore, the series product is enhanced with excellent performance in protection level, which ensures the stability of UPS working in industrial environment with large dusts.
    Excellent performance in industrial environment protection
        Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard the UPS's security of operation in bad environment.
    N+X parallel redundancy (compatible to battery share in the parallel mode)
        The maximum of the inbuilt parallel mode is 8 UPS without any other external accessories, which helps the customer to extend the system capacity with low cost. N stands for the minimum amount of UPS in the load and X stands for the amount of redundant UPS in the system. The bigger the number of X is, the higher the reliability of the system.
        The advanced controlling strategy is adopted to save the customer's investment by sharing a battery unit in the parallel redundancy mode.
    Intelligent management of battery charging and discharging
        The CUP- controlled advanced intelligent charging of battery enables the UPS's charger to rectify the charging parameter, and provide the optimum charging modes in the answer to the environment, types and amounts of cells, and the using condition of the battery. The scientific charging mode extends the battery's service lifetime. The optional addition to charging units shortens the time duration for the battery units recharging.
    Frontal-board operation and maintenance
        The full consideration of customer's efficiency in using the UPS is embodied in the module design and frontal-board maintenance, which saves time for repairing and improves the machine's usability.
    Twin-channel line input
        The UPS provides customer security in power supply with intelligent choice between two-line input or one-line input according to the actual condition.  
    High-efficient DSP chip
        The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output and reliability.
    Outstanding electric property
        The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help to reduce the power loss of UPS.
        The series UPS is designed to China's power grid with a broader range of input voltage from 210VAC to 475VAC, which ensures that it can be applicable in the awful grid environment or different power supple equipment like generator with its extraordinary input frequency.
        The factor that the technology of IGBT FM intelligent rectifier and inverter is used , the input power factor is as high as 0.99, and the input current harmonic wave is as low as 3% makes the output voltage electric property more extraordinary.
        Powerful overload capacity: the UPS can work normally under the condition of 110-125% load to 10 minutes, and 1 minute in the condition of ;125-150% load. It also has the output short protection capability.
    Flexible battery arrangement
        Flexible arrangement of the amount of accumulators in each battery (32, 30, or 28) can be achieved through the parameter resetting in the CASTLE EX series UPS, which effectively solves the question that the damage of some individual cell may influence the life of the whole battery unit by eliminating the damaged ones from the unit in the process of using UPS. 

    Model

    CASTLE EX 20KS

    CASTLE EX 30KS

    CASTLE EX 40KS

    Rated Capacity

    20KVA/16KW

    30KVA/24KW

    40KVA/32KW

    Input

    Voltage

    210-475VAC

    Frequency

    40-70Hz

    Self-adaptive to 50Hz and 60Hz

    Phase Line

    Three-phase 4 line + earth line

    THDI

    3

    Input Power Factor

    0.99

    Twin-channel Line Input

    Yes

    Battery

    Model

    Valve-control lead-acid storage battery

    Standby Time

    Determined by the amount of external-connected cells

    Output

     Voltage

    220×1±1%)VAC

    Frequency

    50/60Hz

    Phase line

    Three-phase 4 line + earth line

    Rated output power factor

    8

    Overload Capacity

    125% 10min

     

    150%  1min

    Efficiency

    Line Input Mode

    93%

    BAT Mode

    93%

    ECO Mode

    98%

    Intelligent Speed Control of Fan

    yes

    Display Device

    LCD

    I/O voltage, current, frequency, BAT voltage, charging current value, discharging current value, fault display, fault, warning

    LED

    The operation state of UPS

    Warning Devices

    Two ways of alerting: BUZZER sound, lamp signal,

    CON Interface

    RS232,AS400,RS485,Service,EPO, BAT temperature compensation, Intelligent Slot

    Operation

    Environment

    Temperature

    0-40℃

     Humidity

    10-99%

    Weight

    Net Weight

    82Kg

    90Kg

    90Kg

    Gross load

    113Kg

    130Kg

    130Kg

    Size W*D*Hmm(host machine)

    420×663.5×956

    500×700×1150

    500×700×1150