PV1100 Series High Frequency Solar Inverter

Power Range:1000VA 1400VA 2400VA

Type:High Frequency Solar Inverter

Description:. Modified sinewave AC output, wide application range; . Charge current 15/20A adjustable, for model 660W/800W . Inbuilt with 30A PWM solar charge controller

contact now





    • Features
    • Specifications
    • Download
    . Modified sinewave AC output, wide application range;
    . Charge current 15/20A adjustable, for model 660W/800W
    . Inbuilt with 30A PWM solar charge controller
    . Three-steps intelligent charging control
    . Battery reverse protection function
    . Battery cable 10AWG 60cm (double line)
    . Compact size fit for home use, small solar system
    MODEL PV11-1000 PV11-1400 PV11-2400
    Default Battery System Voltage 12VDC 24VDC
    INVERTER OUTPUT Rated Power 1000VA/660W 1400VA/800W 2400VA/1440W
    Waveform Modifided Sine-wave
    Nominal Output Voltage RMS 230V
    Output Voltage Regulation +10/-18%
    Output Frequency 50Hz/60Hz +/-1 Hz
    Inverter Efficiency(Peak) >80%
    Line Mode Efficiency >95%
    Typical Transfer Time Typical 15~20ms 40ms max
    AC INPUT Voltage 230VAC
    Selectable Voltage Range Narrow 170~280VAC
    Wide 90~280VAC
    Frequency Range 50HZ/60HZ (Auto sensing)
    BATTERY Nominal Input Voltage 12VDC 24VDC
    Minimum Start Voltage 10.5VDC 21.0VDC
    Low Battery Alarm 10.5VDC+/-0.4V 21.0VDC+/-0.8V
    Low Battery Cutoff 10.0VDC+/-0.4V 20.0VDC+/-0.8V
    High Voltage Cutoff 15.0VDC+/-0.4V 30.0VDC+/-0.8V
    SOLAR CHARGER & AC CHARGER Maximum PV Charge Current 30A
    DC Voltage 12V/24V atuo work
    Maximum PV Array Power 450W 900W
    MPPT Range @ Operating Voltage 16~55VDC
    Maximum PV Array Open Circuit Voltage 55VDC
    Maximum Efficiency >95%
    Standby Power Consumption <2W
    AC Charger Voltage (Vbat<12.5V) 14.4VDC+/-0.2V 28.8VDC+/-0.4V
    AC Charger Voltage (Vbat>12.5V) 13.7VDC+/-0.2V 27.4VDC+/-0.4V
    AC Charging Current 15A/20A±2A @ PV Charger 0-10A 10A±2A @ PV Charger 0-10A
    8A @ PV Charger 10-20A 3A @ PV Charger 10-20A
    No Charing @ PV Charger 20-30A No Charing @ PV Charger 20-30A
    Maximum Charge Current 30A
    BYPASS & PROTECTION Nominal Input Frequency 50Hz or 60Hz
    Overload Protection (SMPS Load) FUSE
    Output Short Circuit Protection FUSE
    Bypass Breaker Rating 10A
    Max Bypass Current 10Amp
    MECHANICAL SPECIFICATIONS Dimensions (W*H*D) 268*260*90mm
    Net Weight (kg) 3.5 3.5 3.5
    OTHER Operation Temperature Range 0°C to 50°C
    Audible Noise 50dB MAX
    Display LED+LCD
    Loading(20GP/40GP/40HQ) 1700pcs/3400pcs/4100pcs