PV3500 Series Low Frequency Solar Inverter 1-4K

Power Range:1250VA 2000VA 3000VA 4000VA

Type:Low Frequency Solar Inverter

Description:Power range 1.25KVA-4KVA; 12V/24V/48VDC input voltage; Powerful Charge Rate Up to 65Amp; Inbuilt pure copper transformer; Pure sine wave output; LED+LCD display; MPPT solar charge controller 40A 45A 60A.

contact now





    • Features
    • Specifications
    • Download
    · 45/60A MPPT solar charge controller 
    · PV input:145V max 
    · 12V/24V/36V/48V auto work 
    · MPPT efficiency>99% ,peak conversion efficiency>98% 
    · DSP processors architecture ensure high speed and performance 
    · Four-stages charging mode 
    · Protection: PV array short circuit, PV reverse polarity, battery reverse polarity, over charging, output short circuit
    MODEL PV35-1250 PV35-2K PV35-3K PV35-4K
    Default Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC
    INVERTER OUTPUT Rated Power 1250VA/1.0KW 2000VA/1.6KW 3000VA/2.4KW 4000VA/3.2KW
    Surge Rating (20ms) 3.0KW 4.5KW 6.0KW 9.0KW
    Capable Of Starting Electric Motor 1HP 1HP 1.5HP 2HP
    Waveform Pure sine wave/ same as input (bypass mode)
    Nominal Output Voltage RMS 100V/110V/120VAC 220V/230V/240VAC(+/-10% RMS)
    Output Frequency 50Hz/60Hz +/-0.3 Hz
    Inverter Efficiency(Peak) >88%
    Line Mode Efficiency >95%
    Power Factor 0.8
    Typical Transfer Time 10ms(max)
    AC INPUT Voltage 230VAC
    Selectable Voltage Range 96~132VAC/155~280VAC(For Personal Computers)
    Frequency Range 50Hz/60Hz (Auto sensing) 40-80Hz
    BATTERY Minimum Start Voltage 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, *4 for 48VDC)
    Low Battery Alarm 10.5VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
    Low Battery Cutoff 10.0VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
    High Voltage Alarm 16.0VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
    High Battery Voltage Recover 15.5VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
    Idle Consumption-Search Mode <25W when power saver on
    CHARGER Output Voltage Depends on battery type
    Charger AC Input Breaker Rating 10A 30A 30A 30A
    Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
    Maximum Charge Current 35A 20A 25A 65A 45A
    BTS Continuous Output Power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
    BYPASS & PROTECTION Input Voltage Waveform Sine wave (grid or generator)
    Nominal Input Frequency 50Hz or 60Hz
    Overload Protection (SMPS Load) Circuit breaker
    Output Short Circuit Protection Circuit breaker
    Bypass Breaker Rating 10A 15A 20A 30A
    Max Bypass Current 30Amp
    SOLAR CHARGER Maximum PV Charge Current 45A
    DC Voltage 12V/24V atuo work
    Maximum PV Array Power 600W 1200W 600W 1200W 600W 1200W 600W 1200W
    MPPT Range @ Operating Voltage(VDC) 16-100VDC for 12V mode,32-100V for 24V mode
    Maximum PV Array Open Circuit Voltage 100VDC 147VDC
    Maximum Efficiency >98%
    Standby Power Consumption <2W
    MECHANICAL SPECIFICATIONS Mounting Wall mount
    Dimensions (W*H*D) 414*575*211mm
    Net Weight (Solar CHG) kg 23.5 24.5 25.5 29.5
    Shipping Dimensions(W*H*D) 505*701*330mm
    Shipping Weight (Solar CHG) kg 25.5 26.5 27.5 31.5
    OTHER Operation Temperature Range 0°C to 40°C
    Storage Temperature -15°C to 60°C
    Audible Noise 60dB MAX
    Display LED+LCD
    Loading(20GP/40GP/40HQ) 150pcs/300pcs/350pcs