PV3500 Series Low Frequency Solar Inverter 5-15K

Power Range:5KVA 8KVA 7.5KVA 10KVA 12.5KVA 15KVA

Type:Low Frequency Solar Inverter

Description:12V/24V/48VDC input voltage; Powerful Charge Rate Up to 65Amp; Inbuilt pure copper transformer; Pure sine wave output; LED+LCD display; MPPT solar charge controller 40A 45A 60A; MPPT Efficiency max 98%.

contact now





    • Features
    • Specifications
    • Download
    · 45/60A MPPT solar charge controller 
    · PV input:145V max 
    · 12V/24V/36V/48V auto work 
    · MPPT efficiency>99% ,peak conversion efficiency>98% 
    · DSP processors architecture ensure high speed and performance 
    · Four-stages charging mode 
    · Protection: PV array short circuit, PV reverse polarity, battery reverse polarity, over charging, output short circuit
    MODEL PV35-5K PV35-6K PV35-7500 PV35-10K PV35-12.5K PV35-15K
    Default Battery System Voltage 24VDC 48VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC 48VDC
    INVERTER OUTPUT Continuous output power 5KVA/4.0KW 8KVA/4.8KW 7.5KVA/6.0KW 10KVA/8.0KW 12.5KVA/10.0KW 15KVA/12.0KW
    Surge rating (20ms) 12.0KW 15.0KW 18.0KW 24.0KW 30.0KW 36.0KW
    Capable of starting electric motor 2HP 3HP 3HP 4HP 5HP 6HP
    Output waveform Pure sine wave/ same as input (bypass mode)
    Inverter efficiency (Peak) >88%
    Line mode efficiency >95%
    Power factor 0.8
    Nominal output voltage RMS 220V/230V/240VAC(+/-10% RMS)
    Output frequency 50Hz/60Hz +/-0.3 Hz
    Short circuit protection Yes(1sec after fault)
    Typical transfer time 10ms(max)
    AC INPUT Voltage 230VAC
    Selectable voltage range 155~280VAC(For Personal Computers)
    Frequency range 50Hz/60Hz (Auto sensing) 40-80Hz
    BATTERY Minimum start voltage 20.0VDC/21.0VDC for 24VDC mode (40.0VDC/42.0VDC for 48VDC mode)
    Low battery alarm 21.0VDC+/-0.3V for 24VDC mode (42.0VDC+/-0.6V for 48VDC mode)
    Low battery cutoff 20.0VDC+/-0.3V for 24VDC mode (40.0VDC+/-0.6V for 48VDC mode)
    High voltage alarm 32.0VDC+/-0.3V for24VDC mode (64.0VDC+/-0.6V for 48VDC mode)
    High battery voltage recover 31.0VDC+/-0.3V for 24VDC mode (62.0VDC+/-0.6V for 48VDC mode)
    Idle Consumption-Search Mode <25W when power saver on
    AC CHARGER Output Voltage Depends on battery type
    Charger AC Input Breaker Rating 30A 30A 30A 40A 50A 63A
    Max charge power rating 1/3 Rating power
    Overcharge Protection S.D. 31.4VDC for 24VDC mode(62.8VDC for 48VDC mode)
    Maximum Charge Current 65A 35A 65A 40A 65A 50A 70A 80A 100A
    BTS Continuous Output Power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
    BYPASS & PROTECTION Input Voltage Waveform Sine wave (grid or generator)
    Nominal voltage 220V/230V/240VAC
    Max input AC voltage 300VAC for 230VAC HV mode
    Nominal input frequency 50Hz or 60Hz
    Overload Protection (SMPS Load) Circuit breaker
    Output Short Circuit Protection Circuit breaker
    Bypass Breaker Rating 40A 40A 40A 50A 63A 63A
    Max Bypass Current 40Amp 80Amp
    Rated voltage 24VDC/48VDC
    PV open circuit voltage Operational max =145VDC temperature corrected VOC
    SOLAR CHARGER Maximum PV Charge Current 60A 60A(120A Optional)
    DC Voltage 24V/48V atuo work 48V
    Maximum PV Array Power 1600W 3200W 1600W 3200W 1600W 3200W 3200W(6400W for 120A Optional)
    MPPT Range @ Operating Voltage(VDC) 32-145VDC FOR 24V mode, 64-145V for 48V mode 64-145VDC
    Maximum PV Array Open Circuit Voltage 147VDC 147VDC
    Maximum Efficiency >98%
    Standby Power Consumption <2W
    MECHANICAL SPECIFICATIONS Mounting Wall mount
    Dimensions (W*H*D) 414*575*211mm 414*645*211mm
    Net Weight (Solar CHG) kg 38+2.5 48+2.5 49+2.5 60+2.5 66+2.5 70+2.5
    Shipping Dimensions(W*H*D) 505*701*330mm 505*771*330mm
    Shipping Weight (Solar CHG) kg 40+2.5 50+2.5 51+2.5 62+2.5 68+2.5 72+2.5
    OTHER Operation Temperature Range 0°C to 40°C
    Storage Temperature -15°C to 60°C
    Audible Noise 60dB MAX
    Display LED+LCD
    Loading(20GP/40GP/40HQ) 140pcs/280pcs/320pcs

    ------Separator----------------------------