B Series 500VA-1200VA UPS(Ruby star)

Power Range:500VA-1200VA

Type:offline UPS

Description:The Ruby star UPS features unsurpassed reliability for regions or countries with chronic voltage problems .Includes and advanced multi-stage surge suppressor that protects from surges and spikes via AC input fax or DSL lines.

contact now





    • Features
    • Specifications
    Office, PC and Small electronic equipments
    • Automatic buck and boost AVR function, wide input voltage 145-280VAC.   BYPASS outlet available, user can connect equipment of heavy load without damaging UPS.
    • Advanced automatic constant charging circuit, prolongs battery life.  Battery low voltage, overload & short circuit protection.
    • Lead-Acid, maintenance free battery inside, provides strong power to users.
    • Boost and buck AVR (Auto voltage regulation).
    • Fully digitized microprocessor controlled.
    • Energy saving function (UPS green mode).
    • 50/60Hz frequency auto sensing and selection.
    • Cold start function (DC power on).
    • Lightning and surge protection.Short circuit and overload protection.
    • Advanced battery management (ABM technology).
    • Tel/Modem internet surge suppression.  Automatically charging when UPS off.
    • History record of power failure events.
    • Back up, on-line, battery status, power status display by software.
    • Battery charge current: 1.8A
    Offline UPS Model B500 B600 B650 B800 B1000 B1200
    Rated power(VA) 500VA 600VA 650VA 800VA 1000VA 1200VA
    Rated power(W) 300W 360W 390W 450W 600W 700W
    AC Input Rated voltage 110/115/120VA or 220/230/240V AC 
    Voltage range 85-150V AC/145VAC-280VAC
    Output Phase Single
    Voltage(Btt. Mode) 110/120VAC or 220/230/240VAC
    Wave-form under battery Modified sine wave
    Voltage Battery mode ±10%(auto-sensing) 
    Frequency Range 
    (Batt. Mode)
    60 Hz or 50 Hz ±1 Hz
    Transfer time  Typical 2-6 ms, 10ms max.
    Protection Spike protection  320joules, 2ms 
    Filter  10dB at 0.15MHz , 50dB at30Hz 
    Overload UPS automatic shutdown if overload exceeds 110% of normal 
    value for 30 seconds and 130% for 3 seconds 
    Short circuit  UPS output is cut off immediately or input circuit breaker protection 
    Alarm Battery back-up  Beeping sound every 4 seconds 
    Battery low voltage  Beeping sound every 1 seconds 
    Overload  Continuous beeping sound 
    Battery Type  Sealed maintenance-free lead acid 
    Capacity  1*7ah/12v 1*7ah/12v 1*7ah/12v  1*9ah/12v 2*7ah/12  2*7ah/12
    Recharge time  8 hours to 90% of full capacity 
    Back-up time  Typical 15 min(half) 
    Physical Net weight (kgs) 4.5 4.5 4.5 4.7 9.5 9.5
    Body size(L*W*H)(mm) 305 *85*140 350 * 120 *188 
    Inner box size(mm) 365 *130*210 405*195*288
    master carton(mm) 380*278*440(4pcs/master carton)  420*410*303(2pcs/master)
    GWNW(kgs): 22.5/20KGS 21/20kgs
    Loading 20 ‘ 2340 pcs 1000pcs
    40’ 4800 pcs 2050pcs
    OPERATING 
    ENVIRONMENT
    Humidity 0-90 % RH @ 0- 40°C (non-condensing)
    Noise Level Less than 40dB Less than 45dB
    MANAGEMENT Optional USB/
    RS-232 Port 
    Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC