EH5110 is a new generation of high-frequency online UPS. It adopts advanced DSP digital control technology to effectively improve product performance and system reliability, and achieved higher power density. With the characteristics of small size, light weight and high work efficiency. Effectively solve power problems such as power outage, grid high voltage, grid low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuation, etc., and provide the best power for the load.With a standard 19-inch rack construction for easy to install.
It is suitable for power protection devices such as commercial servers, PC servers and peripherals,communication and network equipment, home office computers and other sophisticated electronic equipment.
Model | H6KR | H6KRS | H10KR | H10KRS |
---|---|---|---|---|
Rated Power | 6KVA/4.8KW | 10KVA/8KW | ||
Input | ||||
Voltage | (176 ~ 276)VAC | |||
Frequency | (46 ~ 54/56 ~ 64)Hz | |||
Power Factor | >0.99 | |||
External battery Standard Voltage | 192VDC | |||
Battery Type | Maintenance-free lead-acid battery | |||
Battery | ||||
Battery Number | — | |||
Output | ||||
Voltage | 220(1±1% )VAC | |||
Synchronize with | Input (Utility Mode) | |||
Frequency | 50(1±0.2%) Hz ( Battery Mode ) | |||
Overload Capacity | 105%-125%:Automatically turns off after 1 minute, or switches to bypass mode when the input is normal; 125%-135%,30 seconds or switch to bypass mode when the input is normal; >135%,Turn off after 0.5 seconds or switch to bypass mode when the input is normal | |||
Output waveform | Pure Sine Wave | |||
Socket | Terminal Block | |||
Others | ||||
Transfer Time | 0ms | |||
Display | LED/LCD Display (Optional) | |||
Automatic restart | After the battery turns off, the UPS can be automatically restarted when the utility power returns to normal. | |||
Warning Alarm | ||||
Battery discharge | One beep every 4 seconds when the input voltage is off; one beep per second when the battery is exhausted | |||
UPS Error | Keep Beeping | |||
Connection | ||||
RS-232 | Intelligent monitoring functions such as Utility abnormal, power outage, battery capacity, and UPS status indication. | |||
Option | SNMP card, AS400 card, USB connection | |||
Surroundings | ||||
Temperature | 0℃~ 40℃ | |||
Humidity | 20%~ 90% | |||
Audible Noise | <55dB | |||
Shape parameter | ||||
Host size (W*D*H)mm | 482.6*600*130 | |||
Battery size (W*D*H)mm | 482.6*600*130 | |||
Host weight (Net weight)kg | 18.3 | 18.5 | 19.2 | 19.5 |