EH5500 Tower Internal Battery Series (1-3KVA)

High Frequency Online UPS

The EH5500 series is a new type high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as power cut-off, Grid over voltage/low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuation and provide best power f or load.


  • With double conversion online design
  • Adopt DSP digital control
  • With LCD+LED real-time display
  • With self- detection function
  • Standard RS232 communication outlet

Live Chat Contact Us



Features

  • With double conversion online design, zero output transfer time.
  • Adopt DSP digital control, excellent performance indicators, more steady and reliable.
  • Adopt the technology of active power factor correction technology (PFC), the input power factor is close to 1, which greatly reduces the pollution to the mains power grid, and achieves the purpose of energy saving and reducing system investment costs.
  • Ultra-wide input voltage range, input voltages available 110V instead of turn to battery power.
  • With LCD+LED real-time display, UPS operating available for detection.
  • With self- detection function, can detect hidden faults of UPS.
  • Cold start by battery without grid Input.
  • Input frequency range 40~70Hz, support various fuel generators.
  • With AC input over voltage, low voltage protection, output overload protection, short circuit protection, temperature protection, battery low voltage warning protection and battery overcharge protection.
  • Output power factor 1.0 max. efficiency reach 95% , reduce loss of UPS.
  • When utility cut-off, the UPS discharge battery in the battery mode; when the city power is recovery ,UPS turn on automatically,and charge battery at the same time, asunattended function.
  • Standard RS232 communication outlet ,connect UPS and computer to realize multifunctional and multi-purpose monitoring and management operations, available SNMP card (optional) to UPS remote monitoring function.

Applications

Widely used in small and medium-sized enterprise data center, small financial system network, industrial automation control system, LAN server, CBS server, Shopping center cashier, bank securities, tax, communications, postal, transportation, Power, medical, industrial control, petrochemical.

ModelH1KH2KH3K
Capacity
Rated Capacity1KVA/1KW2KVA/2KW3KVA/3KW
Input
Input formatL+N+PE
Rated input voltage208/220/230/240VAC
Voltage range110~300VAC
Frequency range50/60±6Hz (Default), ±10Hz (Settable)
Input power factor≥0.99
Input total harmonic distortion≤4% linear load
Output
Output formatL+N+PE
Output voltage208/220/230/240VAC
Output accuracy±1%
Output frequencyFor on-line mode: follow current frequency, battery mode: 50 60Hz±0.1%
Output harmonic distortion≤ 2% linear load; ≤ 4% nonlinear load (PF=0.7)
PF1
Overload capacity

AC Mode:
30min@102%~110% Load
10min@110%~130% Load
30s@130%~150% Load
200ms@ >150% Load
Battery Mode:
1min@102%~110% Load
10s@110%~130% Load
3s@130%~150% Load
200ms@>150% Load

Switching time
Switch to battery mode0ms
Switch to bypass4ms
AC priority modeSupport
Efficiency
AC Mode (Full Load)94.5%@220VAC95.5%@220VAC95.5%@220VAC
Battery Mode for with built-in battery (Full Load)87.5%@24VDC89.5%@48VDC91.5%@72VDC
Battery
Battery typeLead Acid Battery
Battery number7Ah*2/7Ah*37Ah*4/7Ah*67Ah*6/7Ah*8
Chaging currentBuilt-in battery 1K-3K: 1A (Default)  1-2A (Adjustable)
Charging modeTwo-stage/three-stage charging
Display
LCD2×8PIN/Pitch2.54mm, support 128-bit segment code, up to 4 buttons + 4 LEDs, can display operating mode / load / input / output, etc.
Interface
RS-232Support: Windwos 2000/2003/XP/Vista/2008/7/Linux/Unix and MAC
USBWindows Famlly & MAC
Intelligent slot(Optional)SNMP/AS400 Relay Card/RS485
EPO (Optional)Support
Environmental parameters
Operating ambient temperature0~40℃
Operating environment humidity20%~95% (no condensation)
Storage temperature-15~60℃ (batteries: 0~40℃ )
AltitudeThe elevation should not exceed 1000m, 1000m or above, up to 4000 m, reference IEC62040
Noise≤45db
Mechanical Specifications
Dimensions (D*W*H) (mm)385*143*222395*143*222455*190*330
Net Weight (kg)7.5/10.514/1622/26